Temperature Monitor

Using a thermistor in the position shown makes a heat activated sensor. A change in temperature will alter the output of the op amp and energize the relay and light the LED. Swapping the position of the thermistor and 47k resistor makes a cold or frost alarm.

Monday, September 29, 2008

Thermostat

Here introduce the temperature regulator(Thermostat) which used a thermistor for the temperature sensor. This circuit can control a outside system by driving a relay when the temperature of the thermistor becomes a setting temperature. The strict temperature setting can not be done with this circuit like the thermometer. The resistance value of the thermistor changes by the ambient temperature. This circuit changes the change of the resistance value into the change of the voltage using the transistor. Then, it compares that voltage and the voltage of the setting temperature using the voltage comparator and it drives a relay. It is a relatively simple circuit. With this circuit, the difficult point is to handle an analog signal (the temperature change). The characteristic of the thermistor, the transistor and so on has an influence on the performance of the equipment just as it is. Even if the thermistor or the transistor of the same name is used, the same performance (the setting temperature range and so on) isn't sometimes gotten. The design to have considered the ruggedness of the part is possible. This time, I made a circuit based on the result which measured the characteristic of each part. I think that this way becomes reference as the case when there is not data of the part.

Heat Sensitive Switch

At the heart of this heat-sensitive switch is IC LM35 (IC1),which is a linear temperature sensor and linear temperature-to-voltage converter circuit. The converter provides accurately linear and directly proportional output signal in millivolts over the temperature range of 0°C to 155°C. It develops an output voltage of 10 mV per degree centigrade change in the ambient temperature. Therefore the output voltage varies from 0 mV at 0°C to 1V at 100°C and any voltage measurement circuit connected across the output pins can read the temperature directly.

The input and ground pins of this heat-to-voltage converter IC are connected across the regulated power supply rails and decoupled by R1 and C1. Its temperature-tracking output is applied to the non-inverting input (pin 3) of the comparator built around IC2. The inverting input (pin 2) of IC2 is connected across the positive supply rails via a voltage divider network formed by potmeter VR1. Since the wiper of potmeter VR1 is connected to the inverting input of IC2, the voltage presented to this pin is linearly variable. This voltage is used as the reference level for the comparator against the output supplied by IC1. So if the non-inverting input of IC2 receives a voltage lower than the set level, its output goes low (approximately 650 mV). This low level is applied to the input of the load-relay driver comprising npn transistors T1 and T2. The low level presented at the base of transistor T1 keeps it nonconductive. Since T2 receives the forward bias voltage via the emitter of T1, it is also kept non-conductive. Hence, relay RL1 is in de-energised state, keeping mains supply to the load ‘off’ as long as the temperature at the sensor is low.

Conversely, if the non-inverting input receives a voltage higher than the set level, its output goes high (approximately 2200 mV) and the load is turned ‘on.’ This happens when IC1 is at a higher temperature and its output voltage is also higher than the set level at the inverting input of IC2. So the load is turned on as soon as the ambient temperature rises above the set level. Capacitor C3 at this pin helps iron out any ripple that passes through the positive supply rail to avoid errors in the circuit operation. By adjusting potmeter VR1 and thereby varying the reference voltage level at the inverting input pin of IC1, the temperature threshold at which energisation of the relay is required can be set. As this setting is linear, the knob of potmeter VR1 can be provided with a linear dial caliberated in degrees centigrade.

Therefore any temperature level can be selected and constantly monitored for external act ions like turning on a room heater in winter or a room cooler in summer. The circuit can also be used to activate emergency fire extinguishers, if positioned at the probable fire accident site. The circuit can be modified to operate any electrical appliance. In that case, relay RL1 must be a heavy-duty type with appropriately rated contacts to match the power demands of the load to be operated